INFINITYPOWER · İSTANBUL, TÜRKİYE+90 212 689 86 84

INFINITYPOWER / UPS

DataPower

1–20 kVA

Online double-conversion UPS for IT and sensitive equipment.

Request a quote ↗Original catalogue ↗
DataPower
Representative family configuration from the catalogue.

Models & part numbers

8 catalogue models. Select a model for its own specification table.

Technical labels and values follow the original English catalogue. “/”, blanks and manufacturer inconsistencies are preserved; confirm final model selection with our team.

DataPower Series — Technical Specifications

PDF · page 7 ↗
DataPower Series — Technical Specifications
SpecificationDPS-1000DPS-2000DPS-3000
General
PHASESingle phase with groundSingle phase with groundSingle phase with ground
Capacity(VA/Watts)1000/9002000/18003000/2700
INPUT
Nominal Voltage200/208/220/230/240Vac200/208/220/230/240Vac200/208/220/230/240Vac
Input Voltage Range176-264Vac at 100% load176-264Vac at 100% load176-264Vac at 100% load
Frequency Range45~55Hz/55~65Hz45~55Hz/55~65Hz45~55Hz/55~65Hz
Power Factor≥ 0.99 @Nominal voltage (100% load)≥ 0.99 @Nominal voltage (100% load)≥ 0.99 @Nominal voltage (100% load)
OUTPUT
Output Voltage200/208/220/230/240Vac200/208/220/230/240Vac200/208/220/230/240Vac
Voltage Regulation±1%±1%±1%
Frequency Range(Sychronized Range)45~55Hz/56~64Hz45~55Hz/56~64Hz45~55Hz/56~64Hz
Frequency Range(Batt.Mode)50Hz/60Hz±0.1Hz50Hz/60Hz±0.1Hz50Hz/60Hz±0.1Hz
Current Crest Ratio3:13:13:1
Harmonic Distortion(THDv)≤3% (Linear load) ≤5% (Non-linear load)≤3% (Linear load) ≤5% (Non-linear load)≤3% (Linear load) ≤5% (Non-linear load)
Transfer Time / AC to DCZeroZeroZero
Transfer Time / Inverter to Bypass4ms(Typical)4ms(Typical)4ms(Typical)
WaveformPure SinewavePure SinewavePure Sinewave
EFFICIENCY
AC Mode90% | 91% | 92%Follow the catalogue for more information
Battery Mode95% | 96% | 97%Follow the catalogue for more information
BATTERY
Standard Model / Typical Recharge Time4 hours recover to 90% capacity4 hours recover to 90% capacity4 hours recover to 90% capacity
Standard Model / Numbers2 or 3 | 4 or 6 | 8Follow the catalogue for more information
Standard Model / Typical Recharge Time4 hours recover to 90% capacity4 hours recover to 90% capacity4 hours recover to 90% capacity
Standard Model / Charging Current(max.)1.0A1.0A1.0A
Standard Model / Charging Voltage27.4Vdc±1% | 54.7Vdc±1% | 82.1Vdc±1%Follow the catalogue for more information
Long-run Model / Charging Current(max.)7A/14A(double board) | 6A/12A(double board)Follow the catalogue for more information
Long-run Model / Charging Current(max.)7A/14A(double board) | 6A/12A(double board)Follow the catalogue for more information
Long-run Model / Charging Voltage41.0Vdc/27.4Vdc ±1% | 54.7Vdc/82.1Vdc/109.4Vdc ±1% | 82.1Vdc/109.4Vdc ±1%Follow the catalogue for more information
INDICATORS
LCDLoad level,Battery level,AC mode,Battery mode,Bypass mode,and Fault indicatorsLoad level,Battery level,AC mode,Battery mode,Bypass mode,and Fault indicatorsLoad level,Battery level,AC mode,Battery mode,Bypass mode,and Fault indicators
ALARM
Battery modeSounding every 4 secondsSounding every 4 secondsSounding every 4 seconds
Low BatterySounding every secondSounding every secondSounding every second
OverloadSounding twice every secondSounding twice every secondSounding twice every second
FaultContinously soundingContinously soundingContinously sounding
PHYSICAL
Standard Model / Dimension (D×W×H)mm293x144x209 | 460x191x337Follow the catalogue for more information
Standard Model / Net Weight (kgs)10.0 | 21.0 | 26.0Follow the catalogue for more information
Long-run Model / Dimension (D×W×H)mm293x144x209 | 460x191x337Follow the catalogue for more information
Long-run Model / Net Weight (kgs)5.6 | 11.0 | 11.5Follow the catalogue for more information
ENVIRONMENT
Humidity20~90% RH @ 0~40 oC (Non-condensing)20~90% RH @ 0~40 oC (Non-condensing)20~90% RH @ 0~40 oC (Non-condensing)
Noise level<50%dB @ 1 Meter<50%dB @ 1 Meter<50%dB @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux,FreeBSD and MACSupports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux,FreeBSD and MACSupports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux,FreeBSD and MAC
Optional SNMPPower management from SNMP manager and web browserPower management from SNMP manager and web browserPower management from SNMP manager and web browser

DataPower Series — Technical Specifications

PDF · page 9 ↗
DataPower Series — Technical Specifications
SpecificationDPS-6000DPS-10K1-1
General
Capacity (VA/Watts)6k / 5.4k10k / 9k
INPUT
Nominal voltage220/230/240Vac220/230/240Vac
Operating voltage range120~276Vac120~276Vac
Operating frequency range50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)
Power factor≥0.99≥0.99
Bypass voltage rangeMax.voltage: 220V: +25%(optional +10%,+15%,+20% ) 230V: +20% (optional +10%,+15%) 240V: +15% (optional +10%) Min.voltage: -45% (optional -20%,-30%)Max.voltage: 220V: +25%(optional +10%,+15%,+20% ) 230V: +20% (optional +10%,+15%) 240V: +15% (optional +10%) Min.voltage: -45% (optional -20%,-30%)
ECO rangeSame as the bypassSame as the bypass
Harmonic distortion (THDi)<3%(100% linear load)<3%(100% linear load)
Generator inputSupportSupport
OUTPUT
Rated voltage220/230/240Vac220/230/240Vac
Power factor0.90.9
Voltage regulation±1%±1%
Frequency / Line Mode±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
Frequency / Bat. Mode50/60(±0.1)Hz50/60(±0.1)Hz
Crest factor3:13:1
Harmonic distortion (THDv)≤2% with linear load ≤5% with non-linear load≤2% with linear load ≤5% with non-linear load
Efficiency>95%>95%
BATTERY
Battery voltage±96/108/120Vdc (optional)±96/108/120Vdc (optional)
Capacity (standard unit)12V/7Ah/9Ah12V/7Ah/9Ah
Typical recharge time)6~8 hours (to 90% of full capacity)6~8 hours (to 90% of full capacity)
Charge current1A(Standard unit); Long run unit Max.current10A(charge current can be set according to battery capacity installed)1A(Standard unit); Long run unit Max.current10A(charge current can be set according to battery capacity installed)
SYSTEM FEATURES
Transfer timeMains to Battery:0ms; Mains to Bypass:0msMains to Battery:0ms; Mains to Bypass:0ms
Overload / Line ModeLoad≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediatelyLoad≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediately
Overload / Bypass Mode40A(Breaker) | 60A(Breaker)Follow the catalogue for more information
Short circuitHold Whole SystemHold Whole System
OverheatLine Mode: Turn to Bypass; Backup Mode: Shut down UPS immediatelyLine Mode: Turn to Bypass; Backup Mode: Shut down UPS immediately
Low battery voltageAlarm and Switch offAlarm and Switch off
Self-diagnosticsUpon Power On and Software ControlUpon Power On and Software Control
BatteryAdvanced Battery ManagementAdvanced Battery Management
Audible & Visual alarmsLine Failure, Battery Low, Overload, System FaultLine Failure, Battery Low, Overload, System Fault
LED & LCD displayLine Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Overload & UPS FaultLine Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Overload & UPS Fault
LCD displayInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup TimeInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup Time
Comunication interfaceRS232,USB,SNMP card(optional), Parallel card(optional), Relay card (optional)RS232,USB,SNMP card(optional), Parallel card(optional), Relay card (optional)
ENVIRONMENTAL
Operating temperature0oC~40oC0oC~40oC
Storage temperature-25oC~55oC-25oC~55oC
Humidity range0~95% (non-condensing)0~95% (non-condensing)
Altitude< 1500m< 1500m
Noise level<55dB<55dB
PHYSICAL
Dimension D×W×H (mm)460x191x720460x191x720
Net weight (kg)54 | 63Follow the catalogue for more information
STANDARDS
SafetyIEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
BATTERY BANK
ModelDPS-BT SeriesDPS-BT Series
Battery type& Max.quantity2×20pcs/7Ah/(9Ah)2×20pcs/7Ah/(9Ah)
PHYSICAL OF BATTERY BANK
Dimensions D×W×H (mm)597×250×616597×250×616
Net weight (kg)122/134122/134

DataPower Series — Technical Specifications

PDF · page 11 ↗
DataPower Series — Technical Specifications
SpecificationDPS-10K3-1DPS-15K3-1DPS-20K3-1
General
Capacity(VA/Watts)10k / 9k15k / 13.5k20k / 18k
INPUT
Nominal voltage380/400/415Vac;(3Ph+N+PE)380/400/415Vac;(3Ph+N+PE)380/400/415Vac;(3Ph+N+PE)
Operating voltage range208~478Vac208~478Vac208~478Vac
Operating frequency range50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)
Power factor≥0.99≥0.99≥0.99
Bypass voltage rangeMax.voltage: 220V: +25%(optional +10%,+15%,+20% ) 230V: +20% (optional +10%,+15%) 240V: +15% (optional +10%) Min.voltage: -45% (optional -20%,-30%)Max.voltage: 220V: +25%(optional +10%,+15%,+20% ) 230V: +20% (optional +10%,+15%) 240V: +15% (optional +10%) Min.voltage: -45% (optional -20%,-30%)Max.voltage: 220V: +25%(optional +10%,+15%,+20% ) 230V: +20% (optional +10%,+15%) 240V: +15% (optional +10%) Min.voltage: -45% (optional -20%,-30%)
Bypass frequency rangeFrequency protection range:±10%Frequency protection range:±10%Frequency protection range:±10%
ECO rangeSame as the bypassSame as the bypassSame as the bypass
Harmonic distortion (THDi)<5%(100% linear load)<5%(100% linear load)<5%(100% linear load)
Generator inputSupportSupportSupport
OUTPUT
Rated voltage220/230/240Vac220/230/240Vac220/230/240Vac
Power factor0.90.90.9
Voltage regulation±1%±1%±1%
Frequency / Bat. Mode50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz
Frequency / Bat. Mode50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz
Crest factor3:13:13:1
Harmonic distortion (THDv)≤2% with linear load ≤5% with non-linear load≤2% with linear load ≤5% with non-linear load≤2% with linear load ≤5% with non-linear load
Efficiency95% | 95.5%Follow the catalogue for more information
BATTERY
Battery voltage±96/108/120Vdc (optional)±96/108/120Vdc (optional)±96/108/120Vdc (optional)
Capacity (standard unit)12V/7Ah/9Ah12V/7Ah/9Ah12V/7Ah/9Ah
Typical recharge time6~8 hours (to 90% of full capacity)6~8 hours (to 90% of full capacity)6~8 hours (to 90% of full capacity)
Charge current1A(10kVA Standard unit) ; Max.current 10A(Long run unit)1A(10kVA Standard unit) ; Max.current 10A(Long run unit)1A(10kVA Standard unit) ; Max.current 10A(Long run unit)
SYSTEM FEATURES
Transfer timeMains to Battery:0ms; Mains to Bypass:0msMains to Battery:0ms; Mains to Bypass:0msMains to Battery:0ms; Mains to Bypass:0ms
Overload / Line ModeLoad≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediatelyLoad≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediatelyLoad≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediately
Overload / Bypass Mode63A(Breaker) | 100A(Breaker) | 125A(Breaker)Follow the catalogue for more information
Short circuitHold Whole SystemHold Whole SystemHold Whole System
OverheatLine Mode: Turn to Bypass; Bat. Mode: Shut down UPS immediatelyLine Mode: Turn to Bypass; Bat. Mode: Shut down UPS immediatelyLine Mode: Turn to Bypass; Bat. Mode: Shut down UPS immediately
Low battery voltageAlarm and Switch offAlarm and Switch offAlarm and Switch off
Self-diagnosticsUpon Power On and Software ControlUpon Power On and Software ControlUpon Power On and Software Control
BatteryAdvanced Battery ManagementAdvanced Battery ManagementAdvanced Battery Management
Audible & Visual alarmsLine Failure, Battery Low, Overload, System FaultLine Failure, Battery Low, Overload, System FaultLine Failure, Battery Low, Overload, System Fault
LED & LCD displayLine Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Overload & UPS FaultLine Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Overload & UPS FaultLine Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Overload & UPS Fault
LCD displayInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup TimeInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup TimeInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup Time
Communication interfaceRS232,USB,SNMP card(optional), Parallel board(optional), Relay card (optional)RS232,USB,SNMP card(optional), Parallel board(optional), Relay card (optional)RS232,USB,SNMP card(optional), Parallel board(optional), Relay card (optional)
ENVIRONMENTAL
Operating temperature0oC~40oC0oC~40oC0oC~40oC
Storage temperature-25oC~55oC-25oC~55oC-25oC~55oC
Humidity range0~95% (non-condensing)0~95% (non-condensing)0~95% (non-condensing)
Altitude< 1500m< 1500m< 1500m
Noise level<55dB | <58dBFollow the catalogue for more information
PHYSICAL
Dimension D×W×H (mm)597×250×655(S)/502×250×616(H) | 502×250×616Follow the catalogue for more information
Net weight (kg)76(S)/35 (H) | 45 | 46Follow the catalogue for more information
STANDARDS
SafetyIEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
BATTERY BANK
ModelDPS-BT SeriesDPS-BT SeriesDPS-BT Series
Battery type& Max.quantity2×20pcs/7Ah(9Ah)2×20pcs/7Ah(9Ah)2×20pcs/7Ah(9Ah)
PHYSICAL OF BATTERY BANK
Dimensions D×W×H (mm)597×250×616597×250×616597×250×616
Net weight (kg)122/134122/134122/134
Catalogue features and options · PDF 6
Data Power Series
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
1kVA To 3kVA (0.9 PF) Tower
Features
• High power density
• Online double conversion with full digital control
• Wide input voltage range: 110~300Vac
• Input power factor 0.99 with PFC
3 kinds of LCD can be selected
• Selectable output voltage: 208/220/230/240Vac
• Smart charger design for optimized battery
performance
• Maximum charging current can be expanded to 12A
(Long run unit)
Colourful Blue LCD Advanced
• Emergency power off function (EPO)
LCD Touch Screen
• ECO mode operation for energy saving
• Generator compatible
• Cold start
• Intelligent fan speed regulation
• Load segment settable (Optional)
• Versatile LCD human-computer interface
• Multiple communication interface: RS232 (USB/
Battery Cabinet Optimized Battery
EPO/
(Optional) Configuration 7/9Ah
• Dry contact card/SNMP card optional)
• Multiple protection function: short-circuit, overload,
overheat, battery overcharge and overdischarge,
output low voltage and fan fault alarm
SNMP card
Dry contact
card
Optional socket Rear Panel
06
Catalogue features and options · PDF 8
Data Power Series
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
6kVA To 10kVA (0.9 PF)
Single Phase input/output (1:1) Tower
Features
• N+X parallel redundancy, support maximum 4
units in parallel
• Online double conversion with full digital
control
• 3-level inverter topology, the efficiency can be
5 Kinds of LCD can be selected
up to 95.5%
• Wide input voltage range: 110~300Vac
• Dual input source (Optional)
• Generator compatible
• Supporting customized shared battery banks
Battery Cabinet Optimized Battery
for parallel system (The battery banks should
(Optional) Configuration
be configured with neutral line)
7/9Ah
• Dual Intelligent card slot for touch screen
version
• (Segment LCD optional)
• Maximum charging current up to 15A Dry contact card
• Cold start function
• Dry contact port optional (4 pins input and 4
pins output)
• Intelligent fan speed regulation
SNMP card
• Low noise design, less than 45dB for 6kVA
• Multiple protection function: short-circuit,
overload, overheat, battery overcharge and
overdischarge, output low voltage and fan
fault alarm
08
Catalogue features and options · PDF 10
Data Power Series
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
10kVA To 20kVA (0.9 PF)
3 PH input/1 PH output (3:1) Tower
Features
• N+X parallel redundancy
• Online double conversion with DSP control
• Input current harmonic: <5%
• Optimization battery group, the quantity of
battery: 16/18/20 pieces (optional)
• factor is changed when selection different
battery quantity 16pc:0.7PF;18PCS:0.8PF;20P Control Panel
CS:0.9PF
• Wide input voltage range: 208~478Vac
• Wide input frequency range(50Hz: 45~55Hz /
60Hz: 54~66Hz)
• Support generator input Relay card
• Support economic(ECO) operation mode
• Self-testing when UPS startup
• Options: SNMP card/Relay card/ Parallel
board
• Cold start SNMP
Parallel board
Battery Cabinets
(Optional) Rear Panel
10