INFINITYPOWER · İSTANBUL, TÜRKİYE+90 212 689 86 84

INFINITYPOWER / UPS

MegaPower

10–80 kVA

Three-phase UPS families for commercial and industrial loads.

Request a quote ↗Original catalogue ↗
MegaPower
Representative family configuration from the catalogue.

Models & part numbers

14 catalogue models. Select a model for its own specification table.

Technical labels and values follow the original English catalogue. “/”, blanks and manufacturer inconsistencies are preserved; confirm final model selection with our team.

MegaPower Series — Technical Specifications

PDF · page 19 ↗
MegaPower Series — Technical Specifications
SpecificationMPS10KMPS15KMPS20KMPS30KMPS40KMPS60KMPS80K
General
Capacity (VA/Watts)10k / 9k15k / 13.5k20k / 18k30k / 27k40k / 36k60k / 54k80k / 72k
INPUT
Nominal input voltage380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)
Operating voltage range305~478 (Full load); 208~478 (50% load)305~478 (Full load); 208~478 (50% load)305~478 (Full load); 208~478 (50% load)305~478 (Full load); 208~478 (50% load)305~478 (Full load); 208~478 (50% load)305~478 (Full load); 208~478 (50% load)305~478 (Full load); 208~478 (50% load)
Operating frequency range45~55Hz at 50Hz / 54~66Hz at 60Hz (auto sensing) | 40~70HzFollow the catalogue for more information
Power factor≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99
Bypass voltage rangeMax.voltage: 220: +25% (Optional +10%, +15%, +20%), 230: +20% (Optional +10%, +15%) 240: +15% (Optional +10%), Min.voltage: -45% (Optional -20%, -30%)Max.voltage: 220: +25% (Optional +10%, +15%, +20%), 230: +20% (Optional +10%, +15%) 240: +15% (Optional +10%), Min.voltage: -45% (Optional -20%, -30%)Max.voltage: 220: +25% (Optional +10%, +15%, +20%), 230: +20% (Optional +10%, +15%) 240: +15% (Optional +10%), Min.voltage: -45% (Optional -20%, -30%)Max.voltage: 220: +25% (Optional +10%, +15%, +20%), 230: +20% (Optional +10%, +15%) 240: +15% (Optional +10%), Min.voltage: -45% (Optional -20%, -30%)Max.voltage: 220: +25% (Optional +10%, +15%, +20%), 230: +20% (Optional +10%, +15%) 240: +15% (Optional +10%), Min.voltage: -45% (Optional -20%, -30%)Max.voltage: 220: +25% (Optional +10%, +15%, +20%), 230: +20% (Optional +10%, +15%) 240: +15% (Optional +10%), Min.voltage: -45% (Optional -20%, -30%)Max.voltage: 220: +25% (Optional +10%, +15%, +20%), 230: +20% (Optional +10%, +15%) 240: +15% (Optional +10%), Min.voltage: -45% (Optional -20%, -30%)
Bypass frequency rangeFrequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%
ECO rangeSame as bypassSame as bypassSame as bypassSame as bypassSame as bypassSame as bypassSame as bypass
Harmonic distortion (THDi)≤3% (100%non-linear load )≤3% (100%non-linear load )≤3% (100%non-linear load )≤3% (100%non-linear load )≤3% (100%non-linear load )≤3% (100%non-linear load )≤3% (100%non-linear load )
OUTPUT
Output voltage380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)
Power factor0.90.90.90.90.90.90.9
Voltage regulation±1%±1%±1%±1%±1%±1%±1%
Frequency / Bat. Mode50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz
Frequency / Bat. Mode50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz
Crest factor3:13:13:13:13:13:13:1
Harmonic distortion (THD)≤2% with linear load ≤5% with non linear load≤2% with linear load ≤5% with non linear load≤2% with linear load ≤5% with non linear load≤2% with linear load ≤5% with non linear load≤2% with linear load ≤5% with non linear load≤2% with linear load ≤5% with non linear load≤2% with linear load ≤5% with non linear load
Efficiency96.7%Follow the catalogue for more information
BATTERY
Battery voltageStandard unit: ±120Vdc (20pcs 12V9AH); | Standard unit: ±120Vdc (2x20pcs 12V9AH); | Standard unit: ±120Vdc(3x20pcs 12V9AH); | Optional Voltage: ±192V/±204V/±216V/±228V/ ±240Vdc(32/34/36/38/40pcs optional)Follow the catalogue for more information
Charge Current(A) (charge current can be set according to battery capacity installed)Standard unit: 1.35A | Standard unit: 2.7A | Standard unit: 4.05A | Max.current 15A | Max.current 30AFollow the catalogue for more information
SYSTEM FEATURES
Transfer timeUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0ms
OverloadLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypass
Short circuitHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole Syetem
CommunicationUSB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)
ENVIRONMENTAL
Operating temperature0~40 oC0~40 oC0~40 oC0~40 oC0~40 oC0~40 oC0~40 oC
Storage temperature-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)
Humidity range0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)
Altitude< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use
Noise level<55dB | <58dB | <63dBFollow the catalogue for more information
PHYSICAL
Dimension D×W×H (mm)900x250x868900x250x868900x250x868900x250x868828x360x868828x360x868828x360x868
Net weight (kg)115/57 | 170/63 | 171/64 | 223/71 | 73 | 118 | 122Follow the catalogue for more information
STANDARDS
SafetyIEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

MegaPower Series — Long-run — Technical Specifications

PDF · page 21 ↗
MegaPower Series — Long-run — Technical Specifications
SpecificationMPS10K longMPS15K longMPS20K longMPS30K longMPS40K longMPS60K longMPS80K long
General
Capacity (VA/Watts)10k / 9k15k / 13.5k20k / 18k30k / 27k40k / 36k60k / 54k80k / 72k
INPUT
Nominal voltage380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)380/400/415Vac, (3Ph+N+PE)
Operating voltage range208~478Vac208~478Vac208~478Vac208~478Vac208~478Vac208~478Vac208~478Vac
Operating frequency range45~55Hz at 50Hz / 54~66Hz at 60Hz (auto sensing) | 40~70HzFollow the catalogue for more information
Power factor≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99≥0.99
Bypass voltage range380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20%(optional +10%,+15% ) 415Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%)380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20%(optional +10%,+15% ) 415Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%)380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20%(optional +10%,+15% ) 415Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%)380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20%(optional +10%,+15% ) 415Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%)380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20%(optional +10%,+15% ) 415Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%)380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20%(optional +10%,+15% ) 415Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%)380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20%(optional +10%,+15% ) 415Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%)
Bypass frequency rangeFrequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%Frequency synchronize tracing range: ±10%
ECO rangeSame as bypassSame as bypassSame as bypassSame as bypassSame as bypassSame as bypassSame as bypass
Harmonic distortion (THDi)≤2% (100%non-linear load )≤2% (100%non-linear load )≤2% (100%non-linear load )≤2% (100%non-linear load )≤2% (100%non-linear load )≤2% (100%non-linear load )≤2% (100%non-linear load )
OUTPUT
Output voltage380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)380/400/415Vac (3Ph+N+PE)
Power factor0.90.90.90.90.90.90.9
Voltage regulation±1%±1%±1%±1%±1%±1%±1%
Frequency / Bat. Mode50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz
Frequency / Bat. Mode50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz50/60(±0.1)Hz
Crest factor3:13:13:13:13:13:13:1
Harmonic distortion (THD)≤2% with linear load ≤3% with non linear load≤2% with linear load ≤3% with non linear load≤2% with linear load ≤3% with non linear load≤2% with linear load ≤3% with non linear load≤2% with linear load ≤3% with non linear load≤2% with linear load ≤3% with non linear load≤2% with linear load ≤3% with non linear load
Efficiency96.5% | 96.7%Follow the catalogue for more information
BATTERY
Battery voltageOptional Voltage: ±96V/±108V/±120V(16/18/20pcs optional)Optional Voltage: ±96V/±108V/±120V(16/18/20pcs optional)Optional Voltage: ±96V/±108V/±120V(16/18/20pcs optional)Optional Voltage: ±192V/±204V/±216V/±228V/ ±240Vdc(32/34/36/38/40pcs optional)Optional Voltage: ±192V/±204V/±216V/±228V/ ±240Vdc(32/34/36/38/40pcs optional)Optional Voltage: ±192V/±204V/±216V/±228V/ ±240Vdc(32/34/36/38/40pcs optional)Optional Voltage: ±192V/±204V/±216V/±228V/ ±240Vdc(32/34/36/38/40pcs optional)
Charge Current(A) (charge current can be set according to battery capacity installed)Max.current 10A | Max.current 15A | Max.current 30AFollow the catalogue for more information
SYSTEM FEATURES
Transfer timeUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0msUtility to Battery : 0ms; Utility to bypass: 0ms
OverloadLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypassLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% change to bypass
Short circuitHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole SyetemHold Whole Syetem
CommunicationUSB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)USB,RS232, RS485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional).LBS port (only 60~80k)
ENVIRONMENTAL
Operating temperature0~40 oC0~40 oC0~40 oC0~40 oC0~40 oC0~40 oC0~40 oC
Storage temperature-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)-25~55oC(No battery)
Humidity range0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)0~95% (Non condensing)
Altitude< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use< 1500m.When>1500m,lower the rated power for use
Noise level<55dB | <58dB | <63dBFollow the catalogue for more information
PHYSICAL
Dimension D×W×H (mm)828x250x868828x250x868828x250x868828x250x868828x360x868828x360x868828x360x868
Net weight (kg)115/57 | 170/63 | 171/64 | 223/71 | 73 | 118 | 122Follow the catalogue for more information
STANDARDS
SafetyIEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1IEC/EN62040-1,IEC/EN60950-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Catalogue features and options · PDF 18
Mega Power Series
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
10kVA To 80kVA (0.9 PF)
Three Phase input/output (3:3)
Features • Self-testing when UPS startup
• 50/60Hz frequency converter mode
• High power density design
• Cold start
• N+X parallel redundancy,support maximum 4
units in parallel • The output can meet 100% unbalanced load
• Online double conversion with DSP control • Multiple protection function: short-circuit,
overload, overheat,
• Input current harmonic: <3%
• battery overcharge and overdischarge, output low
• Wide input voltage range: 208~478Vac
voltage
• Wide input frequency range 40~70Hz
• and fan fault alarm
• Optimization battery group, the quantity of
• Multiple communication interface: USB, RS232,
battery 10~30kVA: 16/18/20pcs (30~50pcs
RS485, Parallel port, Dry contact, Intelligent slot,
supportable)
SNMP card
• 40kVA: 30~50pcs
• (Optional), Dry contact card (Optional), Battery
• Maximum charging current up to 20A (Settable)
temperature sensor (Optional)
• Dual input source (Optional for standard unit)
• Colorful 2.4 inch TFT LCD display and 7 inch
LCD display LCD are optional
• Versatile LCD human-computer interface
• Generator compatible
Segment LCD TFT colourful 7 inch colourful
• ECO mode operation for energy saving
LCD LCD
• Intelligent fan speed regulation
Dry contact card SNMP card
Optimized battery
Battery cabinet SNMP card Parallel cable
configuration
(Optional)
7Ah/9Ah (12V)
18
Catalogue features and options · PDF 20
Mega Power Series Long
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
10kVA To 80kVA (0.9 PF)
Three Phase input/output (3:3)
Features • Wide input frequency range: 45~66Hz
• DC start
• Online–Double conversion
• Communication port: USB/RS232/RS485/
• Output transfer time is 0ms
Parallel port/ dry contact
• PFC technology
• Options: SNMP card/Relay card
• Full digital control (DSP)
• LCD/LED double display
• Output power factor: 0.9
• Intelligent charging management
• Input current harmonic: 2%
• EPO function
• ECO function
• Common battery group
• Charging/Rectifier/Inverter fully digital control
• The output can be meet 100% unbalanced
technology
load
• Optimization battery group, the quantity of
battery: 16/18/20 pieces (optional)
• Wide input voltage range: 208~478Vac
Segment LCD TFT colourful 7 inch colourful
LCD LCD
20