High Efficiency MegaPower Series — Technical Specifications

PDF · page 23 ↗
High Efficiency MegaPower Series — Technical Specifications
SpecificationHMPS 150
General
Capacity(VA/Watts)150k/150k
INPUT
Nominal voltage380/400/415Vac (3Ph+N+PE)
Operating voltage range138~485Vac for 40% load; 305~485Vac for full-load
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power factor≥0.99
Harmonic distortion (THDi)≤2.5% Linear load
Bypass voltage rangeMax.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%)
Frequency protection range50/60Hz±10%
Generator inputSupport
Invertor/Rectifier TopolgyTrasnformerless 3IGBT with PWM
OUTPUT
Output voltage380/400/415Vac (3Ph+N+PE)
Voltage regulation±0.5%
Power factor1.0
Output frequency / Line Mode±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional)
Output frequency / Bat. Mode(50/60±0.2%)Hz
Crest factor3:1
Harmonic distortion (THDv)≤1.5% with linear load ≤2.5% with non linear load
Overload / AC ModeLoad≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150%:turn to bypass immediately
Overload / Bypass Mode135% overload long time; >1000% overload 100ms
EFFICIENCY
Online/HFM97.1%/99%
BATTERY
Battery voltageLI-ion optional Optional Voltage: ±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/4 0/42/44/ 46/48/50pcs optional); 360Vdc~600Vdc (30~50pcs, 30pcs default, 36~50pcs output power factor 1.0; 32~34pcs output power factor 0.9; 30pcs output power factor 0.8) LI-ion optional
Battery voltageLI-ion optional Optional Voltage: ±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/4 0/42/44/ 46/48/50pcs optional); 360Vdc~600Vdc (30~50pcs, 30pcs default, 36~50pcs output power factor 1.0; 32~34pcs output power factor 0.9; 30pcs output power factor 0.8) LI-ion optional
Battery typeLI-ion optional Optional Voltage: ±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/4 0/42/44/ 46/48/50pcs optional); 360Vdc~600Vdc (30~50pcs, 30pcs default, 36~50pcs output power factor 1.0; 32~34pcs output power factor 0.9; 30pcs output power factor 0.8) LI-ion optional
Charge Current (charge current can be set according to battery capacity installed)40A Max.
SYSTEM FEATURES
Transfer timeUtility to Battery: 0ms; Utility to Bypass: 0ms
Backfeed protectionSupport
AlarmOverload, utility abnormal, UPS fault, battery low, etc
ProtectionShort circuit, overload, over temperature, battery low, fan fault alarm
Remote LCDSupport
CommunicationUSB, RS232, RS485, parallel port, dry contact, intelligent slot, LBS, SNMP card (Optional), relay card (Optional)
ENVIRONMENTAL
Operating temperature0oC~40oC
Storage temperature25oC~55oC(No battery)
Humidity range0~95% (Non condensing)
Altitude<1500m, derating required when>1500m
Noise level<62dB
PHYSICAL
Dimension W×D×H (mm)442 x 850 x 1200
Net weight (kg)200
STANDARDS
SafetyIEC/EN62040-1, IEC/EN62477-1