Knight Series — Technical Specifications
PDF · page 33 ↗| Specification | Knight 3600-48 |
|---|---|
| Input (AC) | |
| Nominal voltage | 220/230/240Vac |
| Selectable Voltage Range | 170~280Vac (For Personal Computers) 90~280Vac (For Home Appliances) |
| Frequency | 50/60Hz (Auto Detection) |
| Power factor | >0.9 |
| AC Switch | Optional |
| Generator Input | Support |
| PV String Input(DC) | |
| Max PV Array Open Circuit Voltage Range | 500Vdc |
| Nominal Voltage | 240Vdc |
| Start-up Voltage | 120Vdc |
| Initial Feeding Voltage | 150Vdc |
| MPPT Voltage Range | 120Vdc~450Vdc |
| Number of MPPT Trackers | 1 |
| Max. PV Array Short Circuit Current | 18A |
| Maximum PV Input Power | 4000W |
| DC Switch | Optional |
| AC Output | |
| Nominal AC Output Power | 3600W |
| Nominal AC Voltage | 220/230/240Vac |
| Output Voltage Range | 184~264.5Vac or 195.5~253Vac (Selectable) |
| AC Grid Frequency Range | 50/60Hz±5Hz |
| Max. Output Current | 15.7A |
| Power Factor(cos) | 0.8leading-0.8lagging |
| Battery Mode To Grid Efficiency(Peak) | 93.5% |
| AC Output(Backup) | |
| Nominal output Power | 3600W / 3600VA |
| Nominal Voltage (Batt. Mode) | 220 / 230(Default) / 240Vac ± 5%, User Settable |
| Inverter Voltage Range (PV Mode Narrow) | 184 - 264Vac |
| Inverter Voltage Range (PV Mode Wide) | 100V~264Vac |
| Inverter Voltage Range (PV Mode Rated) | 220 / 230(Default) / 240Vac ± 5%, User Settable |
| Nominal Frequency (Hz) | 50(Default) / 60, User Settable |
| Transfer Time | 10ms typical,15ms max(For Personal Computers) / 20ms typical, 25ms max (For Home Appliances) |
| Waveform | Pure sinewave |
| Battery Mode To Backup Efficiency(Peak) | 93.5% |
| Battery And Charge | |
| Norminal Votage(LiFePO4) | 51.2V |
| Norminal Votage(Lead Acid) | 48V |
| Max. AC charge Current | 60A |
| Max. Solar Charge Current | 60A |
| Max. Charge Current(Solar + AC Charge Current) | 120A (User selectable) |
| Interface & Mechanical | |
| Display | LCD & LED |
| Parallel Function | 6 units |
| Communication Interface | RS232 / USB / Dry Contact / Optional:RS485 / CAN / WIFI |
| Dimension (D*W*H) | 134.0×427.5×460.8 mm |
| Net Weight | 11.8kg |
| Protection | |
| Anti-islanding Protection | Yes |
| Output Over-current Protection | Yes |
| PV Reverse Polarity Protection | Yes |
| Ground Fault Circuit Interrupter | Yes |
| Insulation Detection | Yes |
| AC/DC Surge Protection | DC Type II; AC Type III |
| Yes | Yes | DC Type II; AC Type IIIFollow the catalogue for more information |
| General Specifications | |
| Operating Temperature | -10oC ~ 50oC |
| Storage Temperature | -15oC ~ 60oC |
| Relative Humidity | 5%~ 95%, non-condensing |
| Altitude | <3000m |
| Protection Degree | IP21 |
| RoHS | Yes |
| Certification & Standard | IEC / EN 62109-1&2; IEC / EN 61000-6-1&2&3&4; IEC / EN 61000-3-11; EN 61000-3-12 |