PowerExpand Series — Technical Specifications

PDF · sayfa 29 ↗
PowerExpand Series — Technical Specifications
Teknik özellikPEX10-60KVA
General
Capacity(VA/Watts) / HPM module10k / 9k, 20k / 18k
Capacity(VA/Watts) / HPM module10k / 9k, 20k / 18k
INPUT
Nominal voltage380/400/415Vac, (3Ph+N+PE)
Operating voltage range208~478Vac
Operating frequency range40~70Hz
Power factor≥0.99
Bypass voltage rangeMax.voltage: 220v +25%(optional +10%,+15%,+20% ) 230v 20% (optional +10%,+15%) 240v 15%(optional +10%) Min. voltage: -45% (optional -20%,-30%) Frequency protection range: ±10%
Harmonic distortion (THDi)2%(100% nonlinear load)
Generator inputSupport
OUTPUT
Output voltage380/400/415Vac, (3Ph+N+PE)
Voltage regulation±1%
Power factor0.9
Output frequency1.Line Mode: ±1%,±2%,±4%,±5%,±10% of the rated frequency (optional) 2.Battery Mode: (50/60±0.1%)Hz
Crest factor3:1
Harmonic distortion (THDv)≤2% with linear load ≤5% with non linear load
Efficiency96.5%
BATTERY
Battery voltage±192\±204\±216\±228\±240Vdc; battery quantity(optional)
Charge current / UPS cabinet18A (Max) | 30A (Max) | 60A (Max.)Follow the catalogue for more information
Charge current / HPM module6A (Max.) (charge current can be set according to battery capacity installed)
Backup timeDepends on the capacity of external batteries
SYSTEM FEATURES
Transfer timeUtility to Battery : 0ms; Utility to bypass: 0ms
Overload / Bat. ModeLoad≤110%: last 10min,≤125%: last 1min, ≤150%: last 1S,≥150% shut down UPS immediately
Overload / Bat. ModeLoad≤110%: last 10min,≤125%: last 1min, ≤150%: last 1S,≥150% shut down UPS immediately
Overload / Bypass ModeBreaker (10kVA: 20A / 20kVA:40A)
Short circuitHold whole system
Nose suppressionComplies with EN62040-2
Communication interface1. UPS cabinet : RS232, RS485, Dry Contact, Intelligent slot x 2(SNMP card,Relay card optional) 2. PEX series UPS module: RS232
ENVIRONMENTAL
Operating temperature0oC~40oC
Storage temperature-25oC~55oC
Humidity range0~95% (non-condensing)
Altitude<1500m
Noise level<65dB
PHYSICAL
Dimension D×W×H (mm) / HPM module443x580x131 (3U)
Dimension D×W×H (mm) / HPM module443x580x131 (3U)
Net weight (kg) / UPS cabinet149 | 152 | 290Follow the catalogue for more information
Net weight (kg) / UPS cabinet10kVA/26; 20kVA/31
STANDARDS
SafetyIEC/EN62040-1,IEC/EN60950-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8