INFINITYPOWER / UPS
DataPower+
1–10 kVA
Farklı giriş yapılandırmalarıyla esnek online güç koruması.
Teklif isteyin ↗Orijinal katalog ↗
Modeller ve parça numaraları
8 katalog modeli. Modele özel teknik tablo için bir model seçin.
Teknik etiketler ve değerler orijinal İngilizce kataloğu izler. “/”, boş değerler ve üretici tutarsızlıkları korunmuştur; nihai model seçimini ekibimizle doğrulayın.
DataPower+ Series — Technical Specifications
PDF · sayfa 13 ↗| Teknik özellik | DPPS-1000 | DPPS-1500 | DPPS-2000 | DPPS-3000 |
|---|---|---|---|---|
| General | ||||
| Capacity (VA/Watts) | 1000/900 | 1500/1350 | 2000/1800 | 3000/2700 |
| INPUT | ||||
| Rated Voltage | 200/208/220/230/240Vac | 200/208/220/230/240Vac | 200/208/220/230/240Vac | 200/208/220/230/240Vac |
| Voltage Range | 110~290Vac | 110~290Vac | 110~290Vac | 110~290Vac |
| Frequency Range | 45~65Hz(auto-detect) | 45~65Hz(auto-detect) | 45~65Hz(auto-detect) | 45~65Hz(auto-detect) |
| Power Factor | ≥0.98 | ≥0.98 | ≥0.98 | ≥0.98 |
| Bypass Voltage Range | Max.voltage: +15%(optional +5%,+10%,+25% ) Min. voltage: -45% (optional-15% -20%,-30%) Frequency protection range: ±10% | Max.voltage: +15%(optional +5%,+10%,+25% ) Min. voltage: -45% (optional-15% -20%,-30%) Frequency protection range: ±10% | Max.voltage: +15%(optional +5%,+10%,+25% ) Min. voltage: -45% (optional-15% -20%,-30%) Frequency protection range: ±10% | Max.voltage: +15%(optional +5%,+10%,+25% ) Min. voltage: -45% (optional-15% -20%,-30%) Frequency protection range: ±10% |
| Generator Input | Support | Support | Support | Support |
| OUTPUT | ||||
| Rated Voltage | 200/208/220/230/240Vac | 200/208/220/230/240Vac | 200/208/220/230/240Vac | 200/208/220/230/240Vac |
| Power Factor | 0.9 | 0.9 | 0.9 | 0.9 |
| Voltage Regulation | ±2% | ±2% | ±2% | ±2% |
| Frequency / Utility Mode | 50Hz or 60Hz(Synchronized to Mains) | 50Hz or 60Hz(Synchronized to Mains) | 50Hz or 60Hz(Synchronized to Mains) | 50Hz or 60Hz(Synchronized to Mains) |
| Frequency / Battery Mode | 50/60Hz±0.02Hz | 50/60Hz±0.02Hz | 50/60Hz±0.02Hz | 50/60Hz±0.02Hz |
| Crest Factor | 3:1 | 3:1 | 3:1 | 3:1 |
| THDv | ≤3% with linear load ≤5% with non linear load | ≤3% with linear load ≤5% with non linear load | ≤3% with linear load ≤5% with non linear load | ≤3% with linear load ≤5% with non linear load |
| Efficiency / Battery Mode(full load) | >90% | >90% | >90% | >90% |
| Efficiency / Battery Mode(full load) | >90% | >90% | >90% | >90% |
| Efficiency / ECO Mode(full load) | >99% | >99% | >99% | >99% |
| BATTERY | ||||
| Standard Model / Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity |
| Standard Model / Numbers | 2 | 3 | 4 | 6Follow the catalogue for more information | |||
| Standard Model / Typical Recharge Time | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity | 4 hours recover to 90% capacity |
| Standard Model / Charging Current(max.) | 1.4A | 1.4A | 1.4A | 1.4A |
| Standard Model / Charging Voltage | 27.4Vdc±1% | 41.0Vdc±1% | 54.7Vdc±1% | 82.1Vdc±1%Follow the catalogue for more information | |||
| Long-run Model / Charging Current(max.) | 6A/12A(double board) | 7A/14A(double board)Follow the catalogue for more information | |||
| Long-run Model / Charging Current(max.) | 6A/12A(double board) | 7A/14A(double board)Follow the catalogue for more information | |||
| Long-run Model / Charging Voltage | 27.4Vdc±1% | 41.0Vdc±1% | 54.7Vdc±1% | 82.1Vdc±1%Follow the catalogue for more information | |||
| SYSTEM FEATURES | ||||
| Transfer time | Utility to Battery : 0ms; Utility to bypass< 4ms | Utility to Battery : 0ms; Utility to bypass< 4ms | Utility to Battery : 0ms; Utility to bypass< 4ms | Utility to Battery : 0ms; Utility to bypass< 4ms |
| Overload / Bat. Mode | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely |
| Overload / Bat. Mode | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely | Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely |
| Overload / Bypass Mode | Load > 130%: 60S then shut down output | Load > 130%: 60S then shut down output | Load > 130%: 60S then shut down output | Load > 130%: 60S then shut down output |
| Audible & Visual | Line Failure, Battery Low, Overload, System Fault | Line Failure, Battery Low, Overload, System Fault | Line Failure, Battery Low, Overload, System Fault | Line Failure, Battery Low, Overload, System Fault |
| Status LED & LCD | Load/Battery/Input/Output/Operating Mode Information | Load/Battery/Input/Output/Operating Mode Information | Load/Battery/Input/Output/Operating Mode Information | Load/Battery/Input/Output/Operating Mode Information |
| ENVIRONMENTAL | ||||
| Dimension(W×H×D)mm | 440×86.5×430 | 440×86.5×572 | 440×86.5×696Follow the catalogue for more information | |||
| Weight (Kg) | 15.1 | 18.1 | 22.2 | 25.5Follow the catalogue for more information | |||
| Input Connection | IEC320 C14-10A | IEC320 C20-16A | IEC320-C20-16AFollow the catalogue for more information | |||
| Output Connection | IEC320 C13-10A x 6 | IEC320 C13-10A x 6 &C19-16A x 1Follow the catalogue for more information | |||
| Communication Interface | Smart RS232/USB Port/RJ45/SNMP Card (independent to RS232) | Smart RS232/USB Port/RJ45/SNMP Card (independent to RS232) | Smart RS232/USB Port/RJ45/SNMP Card (independent to RS232) | Smart RS232/USB Port/RJ45/SNMP Card (independent to RS232) |
| Operating Temperature | 0~40oC | 0~40oC | 0~40oC | 0~40oC |
| Storage Temperature | -25~+55oC | -25~+55oC | -25~+55oC | -25~+55oC |
| Humidity | 0~90% (non condensing) | 0~90% (non condensing) | 0~90% (non condensing) | 0~90% (non condensing) |
| Altitude | <1500m.(derating while > 1500m) | <1500m.(derating while > 1500m) | <1500m.(derating while > 1500m) | <1500m.(derating while > 1500m) |
| Noise | <50dB(at 1 meter) | <50dB(at 1 meter) | <50dB(at 1 meter) | <50dB(at 1 meter) |
| BATTERY BANK | ||||
| Model | DPPS-BR04009 | DPPS-BR06009 | DPPS-BR08009 | DPPS-BR12009Follow the catalogue for more information | |||
| Bat.Type&Max.Quantity | 9AH×4 | 9AH×6 | 9AH×8 | 9AH×12Follow the catalogue for more information | |||
| PHYSICAL OF BATTERY BANK | ||||
| Unit Dimensions W×H×D (mm) | 440×86.5×430 | 440×86.5×572 | 440×86.5×696Follow the catalogue for more information | |||
| Weight (Kg) | 12 | 15 | 22 | 32Follow the catalogue for more information | |||
DataPower+ Series — Technical Specifications
PDF · sayfa 15 ↗| Teknik özellik | DPPS-6000 | DPPS-10K1-1 |
|---|---|---|
| General | ||
| Capacity(VA/Watts) | 6k / 5.4k | 10k / 9k |
| INPUT | ||
| Nominal Voltage | 220/230/240Vac(L+N+PE) | 220/230/240Vac(L+N+PE) |
| Operating voltage range | 110~300 (110~300@50% load/176~300@100% load) | 110~300 (110~300@50% load/176~300@100% load) |
| Operating frequency range | 45~55Hz/54~66Hz±0.5Hz | 45~55Hz/54~66Hz±0.5Hz |
| Power factor | ≥0.99 | ≥0.99 |
| Bypass voltage range | 220V: +25%(optional +10%,+15%,+20% ) 230: +20% (optional +10%,+15%) 240: +15% (optional +10%) Min. voltage: -45% (optional -20%,-30%) | 220V: +25%(optional +10%,+15%,+20% ) 230: +20% (optional +10%,+15%) 240: +15% (optional +10%) Min. voltage: -45% (optional -20%,-30%) |
| ECO range | Same as bypass | Same as bypass |
| Harmonic distortion (THDi) | ≤3%(100% linear load) | ≤3%(100% linear load) |
| Generator input | Support | Support |
| OUTPUT | ||
| Output voltage | 220/230/240Vac | 220/230/240Vac |
| Power factor | 0.9 | 0.9 |
| Voltage regulation | ±2% | ±2% |
| Frequency / Bat. Mode | 50/60 (±0.1)Hz | 50/60 (±0.1)Hz |
| Frequency / Bat. Mode | 50/60 (±0.1)Hz | 50/60 (±0.1)Hz |
| Crest factor | 3:1 | 3:1 |
| Harmonic distortion (THDv) | ≤2% with linear load ≤5% with non linear load | ≤2% with linear load ≤5% with non linear load |
| Waveform | Pure Sinewave | Pure Sinewave |
| Efficiency | >95% | >95% |
| BATTERY | ||
| Battery voltage | Optional Voltage: ±96/±108/±120Vdc VRLA or LI-ion | Optional Voltage: ±96/±108/±120Vdc VRLA or LI-ion |
| Typical recharge time | 6~8 hours (to 90% of full capacity) | 6~8 hours (to 90% of full capacity) |
| Charge current | Maximum Current 6A; charge current can be set according to battery capacity installed. | Maximum Current 6A; charge current can be set according to battery capacity installed. |
| SYSTEM FEATURES | ||
| Transfer time | Utility to Battery : 0ms; Utility to bypass: 0ms | Utility to Battery : 0ms; Utility to bypass: 0ms |
| Overload / Line Mode | Load≤110%: last 60min; ≤125%: last 10min; ≤150%: last 1S;>150% turn to bypass mode | Load≤110%: last 60min; ≤125%: last 10min; ≤150%: last 1S;>150% turn to bypass mode |
| Overload / Bypass Mode | 40A(Input breaker) | 60A(Input breaker) |
| Short Circuit | Hold Whole System | Hold Whole System |
| Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately |
| Low battery voltage | Alarm and Switch off | Alarm and Switch off |
| Self-diagnostics | Upon Power On and Software Control | Upon Power On and Software Control |
| EPO (optional) | Shut down UPS immediately | Shut down UPS immediately |
| Battery | Advanced Battery Management | Advanced Battery Management |
| Noise Suppression | Complies with EN62040-2 | Complies with EN62040-2 |
| Audible & Visual alarms | Line Failure, Battery Low, Overload, System Fault | Line Failure, Battery Low, Overload, System Fault |
| Status LED & LCD display | Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault | Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault |
| Reading on the LCD display | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup Time | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup Time |
| Comunication interface | USB,RS232,Parallel Port, SNMPcard/Relay card (optional) | USB,RS232,Parallel Port, SNMPcard/Relay card (optional) |
| ENVIRONMENTAL | ||
| Operating temperature | 0~40oC | 0~40oC |
| Storage temperature | -25~55oC | -25~55oC |
| Humidity range | 0~95% (non condensing) | 0~95% (non condensing) |
| Altitude | <1500m | <1500m |
| Noise level | <45 | <50 |
| PHYSICAL | ||
| Dimension W×H×D (mm) | 440×621.5×86.5 (2U) | 440×621.5×175 (4U)Follow the catalogue for more information | |
| Net Weight (kg) | 15 | 57/65 | 17 | 67Follow the catalogue for more information | |
| STANDARDS | ||
| Safety | IEC/EN62040-1,IEC/EN60950-1 | IEC/EN62040-1,IEC/EN60950-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
DataPower+ Series — Technical Specifications
PDF · sayfa 17 ↗| Teknik özellik | DPPS-6K3-1 | DPPS-10K3-1 |
|---|---|---|
| General | ||
| Capacity(VA/Watts) | 6k / 5.4k | 10k / 9k |
| INPUT | ||
| Nominal Voltage | 380/400/415Vac(3Ph+N+PE) or 220/230/240Vac(L+N+PE) | 380/400/415Vac(3Ph+N+PE) or 220/230/240Vac(L+N+PE) |
| Operating voltage range | 208~478Vac or 120Vac~276Vac | 208~478Vac or 120Vac~276Vac |
| Operating frequency range | 50Hz:45~55Hz;60Hz:54~66Hz(auto sensing) | 50Hz:45~55Hz;60Hz:54~66Hz(auto sensing) |
| Power factor | ≥0.99 | ≥0.99 |
| Bypass voltage range | Max. voltage: 220V: +25%(optional +10%,+15%,+20% ) 230V: +20% (optional +10%,+15%), 240V: +15% (optional +10%) Min. voltage: -45% (optional -20%,-30%) | Max. voltage: 220V: +25%(optional +10%,+15%,+20% ) 230V: +20% (optional +10%,+15%), 240V: +15% (optional +10%) Min. voltage: -45% (optional -20%,-30%) |
| Bypass frequency range | Frequency protection range:±10 | Frequency protection range:±10 |
| ECO range | Same as bypass | Same as bypass |
| Harmonic distortion (THDi) | ≤5%(100% linear load) | ≤5%(100% linear load) |
| Generator input | Support | Support |
| OUTPUT | ||
| Output voltage | 220/230/240Vac | 220/230/240Vac |
| Power factor | 0.9 | 0.9 |
| Voltage regulation | ±1% | ±1% |
| Frequency / Bat. Mode | 50/60(±0.1)Hz | 50/60(±0.1)Hz |
| Frequency / Bat. Mode | 50/60(±0.1)Hz | 50/60(±0.1)Hz |
| Crest factor | 3:1 | 3:1 |
| Harmonic distortion (THDv) | ≤2% with linear load, ≤5% with non linear load | ≤2% with linear load, ≤5% with non linear load |
| Efficiency | >95% | >95% |
| BATTERY | ||
| Battery voltage | ±96/108/120Vdc (optional) | ±96/108/120Vdc (optional) |
| Backup time | Long run unit depends on the capacity of external batteries Estimated remaining time displayed on the LCD | Long run unit depends on the capacity of external batteries Estimated remaining time displayed on the LCD |
| Typical recharge time | 6~8 hours (to 90% of full capacity) | 6~8 hours (to 90% of full capacity) |
| Charge current | Maximum Current 10A; charge current can be set according to battery capacity installed | Maximum Current 10A; charge current can be set according to battery capacity installed |
| SYSTEM FEATURES | ||
| Transfer time | Mains to Battery:0ms; Mains to Bypass:0ms | Mains to Battery:0ms; Mains to Bypass:0ms |
| Overload / Line Mode | Load≤110%:60min; ≤125%:last 10min; ≤150%:last 1min;>150% turn to bypass mode | Load≤110%:60min; ≤125%:last 10min; ≤150%:last 1min;>150% turn to bypass mode |
| Overload / Bypass Mode | 40A(Input breaker) | 60A(Input breaker) |
| Short Circuit | Hold Whole System | Hold Whole System |
| Overheat | Line Mode: Turn to Bypass; Backup Mode: Shut down UPS immediately | Line Mode: Turn to Bypass; Backup Mode: Shut down UPS immediately |
| Low battery voltage | Alarm and Switch off | Alarm and Switch off |
| Self-diagnostics | Upon Power On and Software Control | Upon Power On and Software Control |
| Battery | Advanced Battery Management | Advanced Battery Management |
| Audible & Visual alarms | Line Failure, Battery Low, Overload, System Fault | Line Failure, Battery Low, Overload, System Fault |
| Status LED & LCD display | Line Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault | Line Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault |
| Reading on the LCD display | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup Time | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup Time |
| Comunication interface | RS232,USB,SNMP card(optional), Relay card (optional) | RS232,USB,SNMP card(optional), Relay card (optional) |
| ENVIRONMENTAL | ||
| Operating temperature | 0oC~40oC | 0oC~40oC |
| Storage temperature | -25oC~55oC | -25oC~55oC |
| Humidity range | 0~95% (non condensing) | 0~95% (non condensing) |
| Altitude | <1500m | <1500m |
| Noise level | <55dB | <55dB |
| PHYSICAL | ||
| Dimension W×H×D (mm) | 580×443×131(3U) | 580×443×131(3U) |
| Net Weight (kg) | 23 | 25 |
| STANDARDS | ||
| Safety | IEC/EN62040-1,IEC/EN60950-1 | IEC/EN62040-1,IEC/EN60950-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| BATTERY BANK | ||
| Model | DPPS-BR Series | DPPS-BR Series |
| Battery type& Max.quantity | 7Ah×20 | 9Ah×20 |
| PHYSICAL OF BATTERY BANK | ||
| Dimensions D×W×H (mm) | 720×443×131(3U) | 720×443×131(3U) |
Katalog özellikleri ve seçenekleri · PDF 12
Data Power + Series
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
1kVA To 3kVA (0.9 PF)
RACK/TOWER
Features
• Rack/Tower Convertible Design
• Patented Mimic LCD Display May be Rotated
by Simply Pushing Front Button
Two directions LCD display
• True Online Double Conversion
• High Output Power Factor at 0.9PF
• Comprehensive display allows easy monitoring
and access of UPSstatus
• Smat SNMP works with either USB or RS-232
together
• Hot-Swappable Battery
• Efficiency up to 90%
• Estimated Remaining Time displayed on the
LCD Optional socket Mini dry
contact card
• Support Economic(ECO) Operation Mode
• Matching Battery Pack
• Optional Powerful Charger
Multifunctional
• Cold Start
bracket
• Power Shedding May Turn Off Uncritical Load
Easy for maintenance,
in Battery Backup
hot-swappable battery
• Emergency Power Off
• Frequency Converter Mode Is Settable
Battery Cabinets Rack-Tower
(Optional) convertible
12
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
1kVA To 3kVA (0.9 PF)
RACK/TOWER
Features
• Rack/Tower Convertible Design
• Patented Mimic LCD Display May be Rotated
by Simply Pushing Front Button
Two directions LCD display
• True Online Double Conversion
• High Output Power Factor at 0.9PF
• Comprehensive display allows easy monitoring
and access of UPSstatus
• Smat SNMP works with either USB or RS-232
together
• Hot-Swappable Battery
• Efficiency up to 90%
• Estimated Remaining Time displayed on the
LCD Optional socket Mini dry
contact card
• Support Economic(ECO) Operation Mode
• Matching Battery Pack
• Optional Powerful Charger
Multifunctional
• Cold Start
bracket
• Power Shedding May Turn Off Uncritical Load
Easy for maintenance,
in Battery Backup
hot-swappable battery
• Emergency Power Off
• Frequency Converter Mode Is Settable
Battery Cabinets Rack-Tower
(Optional) convertible
12
Katalog özellikleri ve seçenekleri · PDF 14
Data Power + Series
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
6kVA To 10kVA (0.9 PF)
Single Phase input/output (1:1)
RACK/TOWER
2U UPS+2U Lithium 2U UPS+3U 4U UPS VRLA
Battery Pack VRLA Battery Pack Battery Built-in
Features • Cold start function (Only for VRLA battery)
• Dual Intelligent card slot for touch screen
• Lithium or VRLA battery selectable
version (Segment LCD optional)
• Wide input voltage range: 110~300Vac
• Dry contact port optional (4 pins input and 4
• Dual input source (Optional)
pins output)
• Generator compatible
• Rail (Optional)
• Support customized common battery banks, when
• PDU with maintenance bypass switch (Optional)
UPSs are used in parallel and only for VRLA version
• Intelligent fan speed regulation
• (The battery banks should be configured with
• Low noise design, less than 45dB for 6kVA
neutral line)
• Multiple protection function: short-circuit, overload,
• 4U Standard version is available with external
overheat, battery overcharge and overdischarge,
battery port (Optional)
output low voltage and fan fault alarm
• Programmable receptacles
• IEC62619/UL1973/UN 38.3 certified lithium
• The 3.5 in touchscreen supports both lithium and
battery pack
VRLA battery versions, the three segment LCDs
are compatible with VRLA version only
• Multiple communication interface: RS232/USB/
RS485/EPO/PDU signal/Battery temperature
signal/Battery group signal/Dual Intelligent card
slot (Mini card slot optional)
• Maximum charging current up to 15A
Multifunctional The 3.5 inch touch screen LCD
Bracket panel can be rotated (Touch
screen is gravity sensing)
Mini Dry Mini SNMP
Contact card
card Dry Contact SNMP
card card
6-10kVA 230V (L-N) 5 Kinds of LCD can be selected
14
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
6kVA To 10kVA (0.9 PF)
Single Phase input/output (1:1)
RACK/TOWER
2U UPS+2U Lithium 2U UPS+3U 4U UPS VRLA
Battery Pack VRLA Battery Pack Battery Built-in
Features • Cold start function (Only for VRLA battery)
• Dual Intelligent card slot for touch screen
• Lithium or VRLA battery selectable
version (Segment LCD optional)
• Wide input voltage range: 110~300Vac
• Dry contact port optional (4 pins input and 4
• Dual input source (Optional)
pins output)
• Generator compatible
• Rail (Optional)
• Support customized common battery banks, when
• PDU with maintenance bypass switch (Optional)
UPSs are used in parallel and only for VRLA version
• Intelligent fan speed regulation
• (The battery banks should be configured with
• Low noise design, less than 45dB for 6kVA
neutral line)
• Multiple protection function: short-circuit, overload,
• 4U Standard version is available with external
overheat, battery overcharge and overdischarge,
battery port (Optional)
output low voltage and fan fault alarm
• Programmable receptacles
• IEC62619/UL1973/UN 38.3 certified lithium
• The 3.5 in touchscreen supports both lithium and
battery pack
VRLA battery versions, the three segment LCDs
are compatible with VRLA version only
• Multiple communication interface: RS232/USB/
RS485/EPO/PDU signal/Battery temperature
signal/Battery group signal/Dual Intelligent card
slot (Mini card slot optional)
• Maximum charging current up to 15A
Multifunctional The 3.5 inch touch screen LCD
Bracket panel can be rotated (Touch
screen is gravity sensing)
Mini Dry Mini SNMP
Contact card
card Dry Contact SNMP
card card
6-10kVA 230V (L-N) 5 Kinds of LCD can be selected
14
Katalog özellikleri ve seçenekleri · PDF 16
Data Power + Series
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
6kVA To 10kVA (0.9 PF)
3 PH input/ 1 PH output (3:1)
RACK/TOWER
Features
• Online-Double conversion
• Output transfer time is 0ms
• PFC technology
• Full digital control (DSP)
• Output power factor: 0.9
• Input current harmonic: <5%
• ECO function
• Charging/Rectifier/Inverter fully digital control
technology
• Optimization battery group, the quantity of
battery: 16/18/20 pieces (optional)
• Wide input voltage range: 208~478Vac or 120~276Vac
• Wide input frequency range: 45-55Hz/54-66Hz
The LCD panel can be rotated
• Self-testing when UPS startup
• Input over/under-voltage protection
• Automatic bypass
• DC start
• Comunication port: USB , RS232
• Options: SNMP card / Relay card
Control Panel Battery Cabinets
(Optional)
16
--------------------------------------
ONLINE DOUBLE CONVERSION UPS
6kVA To 10kVA (0.9 PF)
3 PH input/ 1 PH output (3:1)
RACK/TOWER
Features
• Online-Double conversion
• Output transfer time is 0ms
• PFC technology
• Full digital control (DSP)
• Output power factor: 0.9
• Input current harmonic: <5%
• ECO function
• Charging/Rectifier/Inverter fully digital control
technology
• Optimization battery group, the quantity of
battery: 16/18/20 pieces (optional)
• Wide input voltage range: 208~478Vac or 120~276Vac
• Wide input frequency range: 45-55Hz/54-66Hz
The LCD panel can be rotated
• Self-testing when UPS startup
• Input over/under-voltage protection
• Automatic bypass
• DC start
• Comunication port: USB , RS232
• Options: SNMP card / Relay card
Control Panel Battery Cabinets
(Optional)